NOTICE:
When using a sealing machine, the sealing parts such as the upper and lower heating fast, the cooling block and the sealing band need to be adjusted. Due to the different materials of the product, the upper and lower heating fast, the spacing of the cooling block needs to be adjusted; the sealing band is a wearing part, which is damaged. I need to change when I am; how to adjust these problems, let me tell you.
Due to the different sealing materials and thicknesses, the distance between the upper and lower heating blocks and cooling blocks needs to be adjusted for each product seal.
Adjusting the distance between the upper and lower heating blocks and cooling blocks: Specific method: Turn the upper and lower adjusting screws ① to increase the distance between the upper and lower heating blocks and the cooling block, and turn the upper adjusting screw ① to reduce the distance between the upper and lower heating blocks and the cooling block. distance.
Sealing belt replacement method and adjustment: After the heating block has cooled down, remove the protective cover, rotate the lifting piece on the heating block and the cooling block by 90 °, and raise the two parts; and loosen the embossing wheel and the middle pressing wheel. Spring, remove the guide belt, then push the passive wheel seat toward the heating block, remove the sealing band, replace with a new sealing band, and return the passive wheel, heating block, cooling block, embossing wheel, etc. to the original position. can.