China Coal Group New Energy Import & Export Co.,Ltd

China Coal Group New Energy Import & Export Co.,Ltd

Position: Home » Product Wiki » Conventional Operation Method Of Continuous Band Sealer

Conventional Operation Method Of Continuous Band Sealer

First: Inspection and preparation before starting up
1. This machine adopts 220V single-phase AC power supply and is equipped with a three-pin socket for shell grounding. Before use, check whether the voltage of the power supply meets the requirements, whether the wiring is firm, and whether the bottom line is connected.
2. Adjust the height of the continuous band sealer according to the working conditions of the operator.
3. Check whether the lubrication of each rotating part is good, and inject proper amount of lubricating oil.
4. If the heating tube is used for the first time or when the interval is too long, the electric heating tube may become damp and the insulation resistance may decrease (normally). It should be preheated at low temperature for half an hour before normal operation.
5. Adjust the height and front and back positions of the conveyor table according to the size and filling volume of the packaging bag. For height adjustment, use a special meniscus wrench to loosen the bridge gear nut, adjust it properly and tighten it; adjust the position of the sealing width positioning frame according to the sealing size.
Second: boot operation
1. Press the power switch first, and the indicator light inside the button is on.
2. Turn the speed control knob to adjust the conveyor belt to the required running speed.
3. Press the heating switch, the indicator light in the button is on, and then turn the knob under the temperature controller to make the pointer point to the required temperature value. At this time, the green light in the temperature controller is on, and the ironing head starts to heat up. When the temperature reaches the specified value, the green light When the red light is off, the continuous band sealer can start working.
4. Press the fan switch as needed (the thin layer of material needs to be cooled), the indicator light in the button is on, and the cooling fan is activated.
Third: shutdown operation
1. In order to prolong the service life of the sealing tape, the heating switch must be cut off (the button indicator light is off) before stopping the machine, the temperature of the ironing head will drop, and the sealing tape will continue to run for a period of time.
2. After about half an hour, the fan switch and power switch can be turned off, the whole machine stops, and the indicator light in the button is off.