China Coal Group New Energy Import & Export Co.,Ltd

China Coal Group New Energy Import & Export Co.,Ltd

Position: Home » Industry Info » Sealing Machine Is Prone To Problems And Treatment Methods

Sealing Machine Is Prone To Problems And Treatment Methods

87 Date: 2019-10-11 Tag: Sealing Treatment Methods Sealing Machine

Our company produces a variety of sealing machines. The problems that are easy to occur in the sealing machine are as follows: When the sealing machine is running, there will be inconsistencies in speed, stop and stop. At this time, the back panel of the sealing machine needs to be disassembled. When it is found that there is slack or falling off at the connection between the motor gearbox and the shaft, it is necessary to re-fix the screw so that it can be matched. Then the main motor is operated by the carbon brush contact, so if the wear is particularly serious, and slippery When the ring is not completely in contact or the friction is not good, the sealing machine will not work continuously. In this case, only the same type of carbon brush can be replaced to solve the problem.

Sealing Machine Is Prone To Problems And Treatment Methods

Irregular creases or air bubbles appear at the product seal. These are also common faults. Although they will not leak the inner package, they will affect the quality of the product. The sealer may have such a malfunction, which may be because the equipment has been used for a long time. When high temperature is stuck with plastic debris or dust, etc., this will cause the high temperature belt to be uneven, not smooth, etc., so that the seal is heated unevenly, and bubbles appear after pressing by the cold pressing wheel. At this time, if you replace the high temperature belt or clean it, you can eliminate the fault. Sometimes the irregular bump marks on the cold pressure rubber wheel will be reflected on the packaged items. At this time, there will be many obvious marks on the seal. Make sure the package is beautiful and you need to replace the device.

When the sealing temperature can not be adjusted according to actual needs, the temperature of the equipment can not be well controlled. The fault is mainly caused by the failure of the thermometer, the sealing is easy to burn or the sealing is not strong, the sealing is easy to deform, and the effect is very ugly. The reason for this is that the thermometer is damaged, it needs to be repaired, or the thermocouple is damaged. The temperature cannot be sensed and then transmitted to the thermometer. The thermocouple needs to be replaced. If these can't solve the problem, then it is possible that the quality of the composite itself is not good enough, and the temperature of the heat seal coefficient is different. The sealing machine products produced by our company are of high quality and reasonable price, and have won the favor of many customers at home and abroad.

Sealing Machine Is Prone To Problems And Treatment Methods

skype sail Online Email:export@chinacoalintl.com
menu
Home Products Top

+

+

Please leave a message


export@chinacoalintl.com